There are 3 Ratings on AC Induction Motor.
Continuous Rating
- When the rated load is imposed under
the rated voltage and frequency, the continuous rating means that it can
guarantee the continuous operation which will not result in exceeding the
specified temperature and comply with the other requirements.
* Induction Motor
* 2 Pole Motor
Short-time Rating
-When the rated load is imposed under
the rated voltage and frequency, the intermittent rating means the operation
within a specified period of time(ex. 5min, 10min, 30min,etc..) will not result
in exceeding the specified temperature and comply with the other requirements.
* Reversible Motor
* Torque Motor
Intermittent Periodic Rating
-When a motor is used with the rated
load under the rated voltage and frequency, the interactive rating means that
the cyclic operations of stopping and running with a certain load will not
result in exceeding the specified temperature and comply with the other
requirements.
* Brake Motor
* Clucth Brake Motor
No comments: